Hydraulicspneumatics 947 Leak Testing P1

∆P gauge quickly spots leakage

Jan. 16, 2014
Fluid-power assemblies must be tested for leakage. The three traditional, low-tech approaches for doing so are:

Fluid power assemblies must be tested for leakage. The three traditional, low-tech approaches for doing so are:

  • Filling the assembly with compressed air, then slopping soapy water on it to see if bubbles reveal leaks.
  • Immersing the whole assembly in a water bath, then pressurizing it with air — again, watching for bubbles.
  • Pressurizing the sealed assembly and watching a gauge for pressure decay.

At best, these methods are cumbersome and time-consuming. At worst, they add drying and corrosion problems. All interrupt production flow. A simple, high-speed leakage test, suitable for production work, can be assembled from a differential-pressure gauge, a pair of two-way valves, and a vessel that is known to be leak-free. The circuit is shown in the accompanying illustration.

With the test assembly in place, valve A is opened to pressurize both volumes. The gauge will read zero. Then valves A and B are closed. Because the reference volume holds pressure, any leakage from the test assembly immediately results in a measurable differential that registers on the gauge.

The leakage rate can be calculated from the formula:

L = (∆P × VS)/(PA × t),

where L = flow, in scfm; ∆P = differential pressure, in psi; VS= assembly volume, in ft3; PA = atmospheric pressure, in psi; and t = time, in minutes.

Joe Gordon, chief engineer, Differential Pressure Plus Inc., Branford, Conn., suggested this test configuration. Call him at (203) 481-2545 for more information, or visit www.differentialpressure.com.

Continue Reading

BOOK 2, CHAPTER 12: Fluid Motor Circuits

March 18, 2009
Table of Contents

Motor leakage variations

Oct. 18, 2006
affect low-speed performance

Sponsored Recommendations

All-In-One DC-UPS Power Solutions

March 13, 2024
Introducing the All-In-One DC-UPS, a versatile solution combining multiple functionalities in a single device. Serving as a power supply, battery charger, battery care module,...

Motor Disconnect Switches

March 13, 2024
With experienced Product Engineers and Customer Service personnel, Altech provides solutions to your most pressing application challenges. All with one thought in mind - to ensure...

Industrial Straight-Through Cable Gland

March 13, 2024
Learn more about Altech's cable glands and all they have to offer for your needs!

7 Key Considerations for Selecting a Medical Pump

Feb. 6, 2024
Newcomers to medical device design may think pressure and flow rate are sufficient parameters whenselecting a pump. While this may be true in some industrial applications, medical...