A manufacturer of large castings used in earth graders wanted to be able to press large bushings into different locations on the casting.

A manufacturer of large castings used in earth graders wanted to be able to press large bushings into different locations on the casting. It did not want to have to reposition each casting to access different positions using a C-type press, so it had a gantry-style, movable press built that would roll on rails to access all the holes needing bushings.

The bottom of the gantry had legs with wheels running on top of heavy-duty H-beam rails mounted to the floor. Wheels underneath the top flange of the H beam kept the gantry frame from lifting when pressing.

The schematic provided by the company, reproduced here, shows that the pressing cycle routes hydraulic oil to the cap end of the top cylinders while also sending oil to the rod end of the bottom cylinders. Oil was routed to just the rod ends of the top cylinders to raise the platen because high force was not needed for the return cycle.

However, a problem developed when the top platen was lowered to press on the bushing. The right side would extend faster than the left side for a short distance, and then the left side would take off faster than the right side and cause the platen to tilt in the opposite direction. Technicians switched the outputs of the flow divider to see if the problem was reversed, but it had no effect on what was taking place. They did notice, though, that tank line pressure upstream of the return filter spiked 300 to 350 psi at the beginning of the retract cycle, even though a separate 65-psi check valve bypassed the filter and heat exchanger.

Any idea what was happening?

Find the Solution

Think you know the answer to this month’s problem? Submit your solution via e-mail. All correct answers submitted by October 30, 2018 will be entered into a random drawing for a $50 gift card. The winner will be notified, and his or her name will be printed in a future issue. Only one gift card will be awarded to any participant within a calendar year.

Solution to Last Month’s Challenge:

Coiled-Steel Unwinder Oscillates

Pressure oscillations in load-sensing circuits can be caused by control orifices, such as the 0.042-in. orifice shown on the circuit. The Vickers/Eaton CT-06 relief valve with remote control calls for the remote-control orifice diameter to be 0.040 in. or larger. However, you don’t want it too large, or it will generate heat. Excessive heat is not only evidence of inefficiency but can also degrade the hydraulic fluid. The problem with it being smaller than 0.040 in. is that it can generate noise and oscillations, which was the case here.

The mechanic said he could see daylight through the orifice with a flashlight. However, once he removed the orifice, he found a partial obstruction. Cleaning out the orifice solved the problem.

About the Author

Robert Sheaf | President

Robert J. Sheaf Jr., is the founder and president of CFC Insustrial Training, formerly Certified Fluid Consultants, part of CFC-Solar Inc. CFC-Solar provides technical training, consulting, and field services to any industry using fluid power technology. 

Continue Reading

Motor leakage variations

Oct. 18, 2006
affect low-speed performance

The Impacts of Electrification on Fluid Power Systems

May 15, 2023
Electrification presents challenges as well as opportunities to re-evaluate and improve upon the design of hydraulics and pneumatics.

Sponsored Recommendations

7 Key Considerations for Selecting a Medical Pump

Feb. 6, 2024
Newcomers to medical device design may think pressure and flow rate are sufficient parameters whenselecting a pump. While this may be true in some industrial applications, medical...

How Variable Volume Pumps Work

Feb. 6, 2024
Variable volume pumps, also known as precision dispense pumps, are a positive displacement pump that operates by retracting a piston to aspirate a fluid and then extending the...

What is a Check Valve and How Does it Work?

Feb. 6, 2024
Acheck valve, a non-return or one-way valve, is a mechanical device that allows a gas or liquid to flow freely in one direction while preventing reverse flow in the opposite ...

The Difference Between Calibrated Orifices and Holes

Feb. 6, 2024
Engineers tasked with managing fluid flow talk about both holes and calibrated orifices, but they are two distinct entities. A hole can be any opening, but a calibrated orifice...