Troubleshooting Challenge: Injection Molding Machine Can’t Finish the Job

Aug. 19, 2017
A 20-year-old injection-molding machine was not achieving full pressure, even after rebuilding the pressure clamp and replacing the hydraulic pump.

I was called out to troubleshoot a small injection molding machine that had been made in Japan about 20 years earlier. As is often the case, very little documentation was available. The problem was that circuit pressure would not go high enough to signal that clamp tonnage had been reached. As a result, the machine did not execute the next two steps of its operating cycle.

The clamp desired pressure was set on the pump’s compensator. In this case, the clamp pressure was set at 3,000 psi, but system pressure would only reach about 1,800 psi. All the valves were mounted onto a single manifold. The machine also had a solenoid-operating unloading safety relief, but I don’t know why it was needed.

The hydraulic pump had been replaced, and the clamp cylinder had been rebuilt. The operators told me the system was very dirty because someone had removed the filter element, so the machine ran for months with no filter. Technicians also removed the unloading valve head to ensure the control orifice was clear; all parts were free moving, and the bias spring was not broken.

So what do you think prevented the machine from achieving full pressure?

Find the Solution

Think you know the answer to this month’s problem? Submit your solution by emailing [email protected]. All correct solutions submitted by Sept. 6, 2017, will be entered into a random drawing for a $50 gift card. The winner will be notified, and his or her name will be printed in a future issue. Only one gift card will be awarded to any participant within a calendar year.

Solution to Last Month’s Challenge:

No Pressure on a Simple System

A system that loses all pressure typically is caused by the control orifice of a pilot-operated pressure control being plugged. I disassembled the relief valve and found the main poppet had opened and varnish deposits had lodged in the open position. This was a balanced poppet, so a bias spring is the main force closing it.

When the mechanics inspected the valve, they didn’t realize the main poppet was supposed to move. They had found the problem but didn’t recognize it. This is a perfect example of where some hands-on training would’ve paid off big.

About the Author

Robert Sheaf | President

Robert J. Sheaf Jr., is the founder and president of CFC Insustrial Training, formerly Certified Fluid Consultants, part of CFC-Solar Inc. CFC-Solar provides technical training, consulting, and field services to any industry using fluid power technology. 

Continue Reading

Motor leakage variations

Oct. 18, 2006
affect low-speed performance

The Impacts of Electrification on Fluid Power Systems

May 15, 2023
Electrification presents challenges as well as opportunities to re-evaluate and improve upon the design of hydraulics and pneumatics.

Sponsored Recommendations

7 Key Considerations for Selecting a Medical Pump

Feb. 6, 2024
Newcomers to medical device design may think pressure and flow rate are sufficient parameters whenselecting a pump. While this may be true in some industrial applications, medical...

How Variable Volume Pumps Work

Feb. 6, 2024
Variable volume pumps, also known as precision dispense pumps, are a positive displacement pump that operates by retracting a piston to aspirate a fluid and then extending the...

What is a Check Valve and How Does it Work?

Feb. 6, 2024
Acheck valve, a non-return or one-way valve, is a mechanical device that allows a gas or liquid to flow freely in one direction while preventing reverse flow in the opposite ...

The Difference Between Calibrated Orifices and Holes

Feb. 6, 2024
Engineers tasked with managing fluid flow talk about both holes and calibrated orifices, but they are two distinct entities. A hole can be any opening, but a calibrated orifice...